CapMate
EN

Connecting boat instruments

CapMate shows depth, wind, boat speed, heading, position and AIS vessels from your boat's instruments on your phone and watch. The data arrives over Wi-Fi as NMEA 0183: either the chartplotter shares it itself (B&G, Simrad, Lowrance) or a Wi-Fi gateway on the instrument network does. Raymarine, Garmin and Furuno don't share their data with other apps — they need a gateway. Phones and Wear OS watches join the boat's Wi-Fi themselves; Apple Watch and Garmin watches get the instruments through the phone running CapMate.

ChartplottersNMEA Wi-Fi gatewaysAIS with Wi-FiYour own onboard computer

How CapMate finds your instruments

Turn on instrument reception and the rest happens by itself. CapMate first checks the address where it found the instruments last time, the network router and the addresses of known gateways on their ports, while listening for UDP broadcasts. If nothing is there, it scans its own network: it finds the devices that answer and tries the chartplotter and gateway ports from the list below on them. This usually takes from a couple of seconds to half a minute; the address it finds is remembered, so next time the connection is instant. If a device is found but sends data in the wrong format (for example NMEA 2000 instead of NMEA 0183), CapMate tells you what to change on it.

Chartplotters

B&G · Simrad · Lowrance

Shares data itself
  • B&G — Zeus3, Zeus3S, Vulcan · Zeus2, Zeus Touch + GoFree WIFI-1
  • Simrad — NSS evo3, NSS evo3S, NSO evo3 · NSS evo2 + GoFree WIFI-1
  • Lowrance — HDS Live, HDS Carbon

The plotter shares its instruments and AIS over Wi-Fi itself — no gateway needed.

  1. On the plotter: Settings → Network → NMEA0183 → “NMEA0183 over Ethernet/Wireless” — output must be on, port 10110.
  2. Join the plotter's Wi-Fi with your phone (Settings → Wireless, a network like “Zeus3 xxxx”) or the boat router if the plotter is connected to it. Older models get Wi-Fi from a GoFree WIFI-1 module — the key is on its label.
  3. Back in CapMate the plotter is found automatically, usually within seconds.

The newest models (B&G Zeus S and Zeus SR, Simrad NSX and NSS 4, Lowrance Elite FS) have no NMEA 0183 network output in their documentation; on Lowrance HDS Pro it isn't confirmed. If the plotter isn't found, any NMEA 2000 Wi-Fi gateway from the list will do.

TCP 10110 · 192.168.76.1 · ✓ Tested on a boat 2026-10-06

Raymarine

Needs a Wi-Fi gateway
  • Axiom, Axiom+, Axiom 2, Axiom Pro, Element, eS, gS

Raymarine plotters share data only with the Raymarine app. You need an NMEA 2000 Wi-Fi gateway — it takes the same data from the instrument network.

  1. Connect the gateway to the SeaTalkNG backbone. SeaTalkNG is NMEA 2000: use a SeaTalkNG to NMEA 2000 (DeviceNet) adapter cable.
  2. Make sure NMEA 0183 output is on in the gateway — see the gateway's steps below.
  3. Join the gateway's Wi-Fi with your phone and pick the gateway in the list — CapMate will check it first.

Older SeaTalk1 instruments (ST40, ST60) need a gateway with a SeaTalk1 input: Yacht Devices YDNR-02 or Quark-Elec QK-A034.

Which gateway fits

Garmin

Needs a Wi-Fi gateway
  • GPSMAP, ECHOMAP

Garmin plotters share data over Wi-Fi only with Garmin apps. You need an NMEA 2000 Wi-Fi gateway — it takes the same data from the instrument network.

  1. Connect the gateway to the NMEA 2000 backbone through a free T-connector.
  2. Make sure NMEA 0183 output is on in the gateway — see the gateway's steps below.
  3. Join the gateway's Wi-Fi with your phone and pick the gateway in the list — CapMate will check it first.

If the boat has a Garmin Cortex AIS or a Garmin Signal VHF radio, they share NMEA 0183 over Wi-Fi themselves — no gateway needed: pick “Vesper · Garmin Cortex”.

Which gateway fits

Furuno

Needs a Wi-Fi gateway
  • TZtouch2, TZtouch3, TZtouch XL, NavNet 3D

Furuno plotters share data only with Furuno apps. You need an NMEA 2000 Wi-Fi gateway — it takes the same data from the instrument network.

  1. Connect the gateway to the NMEA 2000 (CAN bus) backbone through a free T-connector.
  2. Make sure NMEA 0183 output is on in the gateway — see the gateway's steps below.
  3. Join the gateway's Wi-Fi with your phone and pick the gateway in the list — CapMate will check it first.

Which gateway fits

NMEA 0183 · SeaTalk1

Needs a Wi-Fi gateway
  • Raymarine ST40, ST60 · NMEA 0183

Instruments without NMEA 2000 — with an NMEA 0183 output or on a SeaTalk1 bus — connect through a Wi-Fi gateway or multiplexer.

  1. NMEA 0183: wire the instrument's output (plotter, GPS, AIS, wind) to the gateway input. Usually 4800 baud, AIS 38400.
  2. SeaTalk1 (Raymarine ST40, ST60): you need a gateway with a SeaTalk1 input — Yacht Devices YDNR-02, Quark-Elec QK-A034 or Vela-Navega NMEA2WiFi.
  3. Join the gateway's Wi-Fi with your phone and pick the gateway in the list.

Which gateway fits

NMEA Wi-Fi gateways

Yacht Devices

Shares data itself
  • YDWG-02, YDNR-02, YDWN-02, YDWR-02, YDEN-02

Works out of the box: the gateway shares NMEA 0183 over Wi-Fi by itself.

  1. Join the gateway's Wi-Fi with your phone: network YDWG (other models: YDNR, YDWN, YDWR), password 12345678.
  2. Back in CapMate the gateway is found automatically (address 192.168.4.1, TCP port 1456).
  3. YDEN-02 is wired: plug it into the boat router — CapMate will find it on the network.

If settings were changed: open 192.168.4.1 in a browser (admin / admin) → NMEA Server → set Server #1 Data Protocol to “NMEA 0183”. If the gateway was switched to client mode, its own network disappears — it is on the boat router’s network, and CapMate finds it there.

TCP 1456 · 192.168.4.1 · From the manufacturer's manual

Actisense

Shares data itself
  • W2K-1, W2K-2, WGX-1, PRO-NDC-1E2K

One setting needed: a data server in NMEA 0183 format.

  1. Join the gateway's Wi-Fi: network w2k-xxxxxx (the gateway's serial number), the password is on its label.
  2. Open 192.168.4.1 in a browser (admin / admin) → Settings → Data Server Settings. Server 1: enable, Protocol TCP, Format “NMEA 0183”, Direction “Transmit Only”, port 60001 → Update.
  3. Back in CapMate the gateway is found automatically.

W2K-2 and WGX-1 are set up the same way — three data servers in the gateway’s web interface; each unit has its own network name and password. PRO-NDC-1E2K connects to the boat router by cable.

TCP 60001, 60002, 60003 · UDP 60001, 60002, 60003 · 192.168.4.1 · From the manufacturer's manual

Digital Yacht

Shares data itself
  • Digital Yacht — NavLink2, WLN10, WLN10 Smart, WLN30, iKommunicate, LANLink
  • Digital Yacht AIS — AIT5000, AIT3000, iAIS

Digital Yacht Wi-Fi gateways and AIS units work out of the box: they share NMEA 0183 over Wi-Fi by themselves.

  1. Join the device's Wi-Fi — a network named after the model plus a code, e.g. NavLink2-xxxx or AIT5000-xxxx (WLN30: DY-WiFi-xxxx). If asked for a password, it's PASS-xxxx with the same four characters as in the network name.
  2. Back in CapMate the device is found automatically (address 192.168.1.1, port 2000; older WLN10 and iAIS units use 169.254.1.1).
  3. LANLink and iKommunicate connect to the boat router by cable. iKommunicate ships with NMEA 0183 output off: Admin Page → Configuration → enable NMEA 0183 over TCP → Apply.

The original WLN10 and the WLN30 accept a single TCP connection — if no data arrives, close other apps. AIT5000 sends over UDP only by default — for iPhone, select TCP in its web interface (192.168.1.1 → Settings).

TCP 2000 · UDP 2000 · 169.254.1.1, 192.168.1.1 · From the manufacturer's manual

Quark-Elec

Shares data itself
  • QK-A032, QK-A034, QK-A035, QK-A036, QK-A026, QK-A027

Works out of the box: the gateway shares NMEA 0183 over Wi-Fi by itself.

  1. Join the gateway's Wi-Fi: a network like A032xxxx or QK-A034xxxx (depends on the model), password 88888888.
  2. Back in CapMate the gateway is found automatically (address 192.168.1.100, TCP port 2000).
  3. To use the gateway through the boat router, switch it to client (Station) mode with the Quark-Elec configuration tool for Windows over USB.

QK-A032, A034 and A036 can send NMEA 2000 as $PCDIN lines — if CapMate reports this while searching, switch the output back to NMEA 0183 in the configuration tool. In access-point mode the gateway takes up to four devices.

TCP 2000 · 192.168.1.100 · From the manufacturer's manual

ShipModul MiniPlex

Shares data itself
  • MiniPlex-3Wi, MiniPlex-3Wi-N2K, MiniPlex-3E, MiniPlex-3E-N2K

Works out of the box: the MiniPlex shares NMEA 0183 over Wi-Fi or Ethernet by itself.

  1. MiniPlex-3Wi: join the Wi-Fi network MiniPlex-xxxxxxxx (serial number), password MiniPlex (address 10.0.0.1, TCP port 10110).
  2. MiniPlex-3E: plug it into the boat router — it gets an address by itself and broadcasts data over UDP to port 10110.
  3. Back in CapMate the multiplexer is found automatically. N2K models convert NMEA 2000 data to NMEA 0183 out of the box.

The MiniPlex accepts a single TCP connection — if no data arrives, close the program on the laptop. For iPhone, enable the TCP server of a MiniPlex-3E in MPX-Config3 (Network Settings).

TCP 10110 · UDP 10110 · 10.0.0.1 · From the manufacturer's manual

Vela-Navega

Shares data itself
  • NMEA2WiFi, NMEA3WiFi

The NMEA2WiFi and NMEA3WiFi multiplexers share NMEA 0183 over Wi-Fi out of the box (UDP, port 2000), including SeaTalk1 data.

  1. Join the Wi-Fi network NMEA2WIFI or NMEA3WIFI, password 12345678.
  2. For iPhone, turn on TCP: open 192.168.4.1 in a browser, set TCP port 10110 and press SET.
  3. Back in CapMate the multiplexer is found automatically.

Over TCP the multiplexer accepts a single connection, over UDP any number of devices. Its access point takes up to five devices.

TCP 10110 · UDP 2000 · 192.168.4.1 · From the manufacturer's manual

Brookhouse iMux

Shares data itself
  • iMux, iMux MK3

The iMux multiplexer shares NMEA 0183 over Wi-Fi by itself.

  1. Join the Wi-Fi network Brookhouse_iMux; if asked for a password, it's BrookhouseXX, where XX is the serial number.
  2. Back in CapMate the iMux is found automatically (address 169.254.1.1, TCP port 2000; iMux MK3: 192.168.1.99, port 10110).

TCP 2000, 10110 · 169.254.1.1, 192.168.1.99 · From the manufacturer's manual

Hat Labs SH-wg

Shares data itself

An open-source NMEA 2000 to Wi-Fi gateway: after first setup it shares NMEA 0183 by itself (UDP 2000 and TCP 2222).

  1. On first power-up, join the Wi-Fi “Configure sh-wg-…” (password abcdabcd) and choose a mode: its own access point or joining the boat router.
  2. Connect the phone to the same network as the gateway.
  3. Back in CapMate the gateway is found automatically.

TCP 2222 · UDP 2000 · From the manufacturer's manual

AIS with Wi-Fi

Vesper · Garmin Cortex

Shares data itself
  • Cortex M1, Cortex V1, XB-8000 · Garmin Signal VHF

AIS transponders with Wi-Fi share AIS, position and some instruments over Wi-Fi by themselves.

  1. Cortex: join the Wi-Fi network CORTEX-xxxxx (hub serial number), the password is on the label under the hub (address 10.1.1.1, TCP port 39150).
  2. XB-8000: join the transponder's Wi-Fi (address 192.168.15.1, TCP port 39150). Garmin Signal VHF radio: turn on Wi-Fi in the radio's menu (Settings → Wi-Fi).
  3. Back in CapMate the device is found automatically, even when it's connected to the boat router.

From the NMEA 2000 network, Cortex passes on only some instruments (wind, depth) — an NMEA 2000 Wi-Fi gateway gives the full set.

TCP 39150 · 10.1.1.1, 192.168.15.1 · From the manufacturer's manual

em-trak

Shares data itself
  • B922, B924, B952, B954

em-trak B900-series AIS transponders with Wi-Fi share AIS, position and NMEA 2000 instruments over Wi-Fi by themselves.

  1. Join the transponder's Wi-Fi: a network like B954_xxxxxxx (model and code), the password is on the label (B952 and B954 default: emtrakais).
  2. Back in CapMate the transponder is found automatically (address 192.168.2.1, TCP port 5000).
  3. Joining the boat router, the protocol and the port are changed in the proAIS2 software or the CONNECT-AIS app.

In access-point mode the transponder streams to only two devices at a time — if the phone gets no data, disconnect other devices from its Wi-Fi.

TCP 5000 · 192.168.2.1 · From the manufacturer's manual

Your own onboard computer

OpenPlotter · Signal K

Shares data itself
  • OpenPlotter, Signal K Server

Signal K Server (OpenPlotter and other builds) shares NMEA 0183 over TCP on port 10110 by default.

  1. In the Signal K admin: Server → Settings — check that “NMEA 0183 over TCP (10110)” is on.
  2. To get NMEA 2000 data too: Server → Plugin Config → enable signalk-to-nmea0183 (tick the sentences you need) and signalk-n2kais-to-nmea0183 for AIS.
  3. Connect the phone to the same network as the computer — CapMate will find the server automatically.

TCP 10110 · From the manufacturer's manual

If the instruments aren't found

Manual connection

If you know the address, enter it yourself: “Connect instruments” → “Enter the address manually” — the device address, port and protocol (TCP or UDP) from the NMEA 0183 server settings of the chartplotter or gateway. To go back to automatic search, tap “Search automatically”.

Home page